Dezincification corrosion resistance alloy
UR30ST
C45470
- corrosion and wear resistance
Dezincification corrosion resistance alloy
C45470
Copper alloy wire for aquaculture pens
Production and sales of bars will be discontinued in March 2028.
If brass alloy contacts to water or seawater, zinc may selectively elute from the brass alloy
surface, which is called "dezincification".
UR30ST is a copper alloy material with excellent dezincification corrosion resistance. We can
provide the optimum materials according to your application. UR30ST is particularly suitable for
aquaculture wire application.

The chemical components of UR30ST is as follows.
| Cu | Pb | Fe | Sn | Ni | Al | Zn | |
|---|---|---|---|---|---|---|---|
| UR30ST | 67.0 | 0.7 | 0.6 | Rem. |
The physical properties of UR30ST is as follows.
| Property | Representative Value |
|---|---|
| UR30ST | |
| Specific Gravity (293K) | 8.5 |
| coeffcient of thermal Expansion (×10-6/K:293~573K) |
21 |
| electrical conductivity (%IACS:293K) |
20 |
| Modulus of Elasticity (kN/mm²:293K) |
103 |
The mechanical properties of UR30ST is as follows.
| alloy | UR30ST |
|---|---|
| Shape | wire |
| size | Ø4 |
| Temper | 1/4H |
| Tensile Strength (N/mm²) |
420 |
| Yield Strength (N/mm²) |
- |
| Elongation (%) |
23 |
| Hardness (HRB) |
52 |
It shows corrosion resistance of UR30ST.
UR30ST have excellent dezincification corrosion resistance.
| Alloy | Ø | ISO 6509 test | JBMA T-303 test | |||
|---|---|---|---|---|---|---|
| maximum corrosion depth (μm) |
average corrosion (μm) |
corrosion form | maximum corrosion depth (μm) |
evaluation | ||
| UR30ST | Ø4 | <10 | <10 | no dezincification | 60 | type Ⅰ |
It satisfies the stress corrosion cracking test by JIS method and ASTM method (both conducted in ammonia atmosphere).
| JIS | ASTM | |
|---|---|---|
| UR30ST | ○ | ○ |
UR30ST has excellent antifouling properties (properties that prevent the adherence of marine organisms such as algae and shellfish), and it is used as a wire of crawls for sea surface culturing.
Galvanized steel wire crawl (4 months passed after installation)
UR30ST crawl (2 years passed after installation)